Quick Reference Guide
For the Dranetz HDPQ Xplorer / Xplorer 400 / Guide / Visa product family.
It is recommended that the user still be familiar with the complete User
Guides for the respective products, as it contains more detailed
information about all of the functions, as well as the specifications and
accessories.
Dranetz
1000 New Durham Road, Edison, New Jersey 08818
Telephone 1-800-372-6832 or 732-287-3680
Fax 732-248-1834
www.dranetz.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - / /

/ / Quick Reference Guide For the Dranetz HDPQ Xplorer / Xplorer 400 / Guide / Visa product family. It is recommended that th

Strany 2 - WARNING

10 Connecting to AC Power Source Power The Xplorer AC adapter can be connected to a 50/60 Specifications Hz, 90-264V AC power input source. CA

Strany 3 - AVERTISSEMENT

11 AC Power The Xplorer can be operated from a 50/60 Hz, Source 120/240V AC power source with or without the battery pack installed. • Voltage rang

Strany 4 - Safety Summary

12 Controls, Indicators and Connectors Top View Voltage and Current Connections - There are four differential voltage and four differential current

Strany 5 - Power switch

13 Left Side View Left Side Panel - contains the power switch, GPS receiver port, and AC adapter input connector. Right Side View Right Side Panel

Strany 6 - TABLE OF CONTENTS

14 Rear View Rear Panel - shows the device mounting hanger located on top if you want to hang the instrument on a panel, wire coil holders to manage

Strany 7

15 MAKING CONNECTIONS WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand th

Strany 8

16 Connecting Voltage Measurement Cables Measurement Cable Set Interconnect Jumpers Description: Voltage measurement cables

Strany 9 - ( ) icon

17 The single fuse voltage adapter kit is used for one single voltage measurement input, while the four fuse voltage adapter kit is used for a t

Strany 10

18  WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth) ground before making any other connections. 

Strany 11 -

19 3 Phase, Four Wire Wye Channels A, B, and C are connected to voltage and current probes. The neutral is connected to common, and is the reference f

Strany 12 - Front View

2 WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand this manual before conne

Strany 13 - Right Side View

20 3 Phase (Floating or Grounded) Delta In this power connection, the Xplorer uses voltage channels A, B, and C as differential inputs with channel A

Strany 14 - Rear View

21 XPLORER UI TOUCHSCREEN FEATURES All Dranetz HDPQ Xplorer screen functions are operable using the color LCD touch screen display. Use your finger an

Strany 15

22 XPLORER TOUCH ICON BUTTONS Touch Icon Buttons There are three touch icon buttons located below the LCD screen - Snapshot, Mini-Report Capture and H

Strany 16

23 XPLORER HOME MONITORING PAGE After the instrument has been powered up and monitoring is turned ON (and subsequently if monitoring is DONE), the Hom

Strany 17

24 Key Instrument Control Functions The major instrument control functionalities are described below: Start / Stop Monitoring You have the option t

Strany 18

25 SETUP MONITORING The Start Monitoring icon takes you to the next page to begin setup monitoring. There are two ways to set up the instrument f

Strany 19 - 3 Phase, Four Wire Wye

26 Measurement Connections The Xplorer can monitor the following power configurations:  Single phase  Split phase  3 Phase Delta  3 Phase Wye  3

Strany 20

27 Automatic Setup for Energy/Demand Automatically configures the setup for monitoring energy/demand. Automatic Setup is a one-stop process using pre-

Strany 21

28 From the Start Menu, press Wizard Setup. You can go through the monitoring setup step-by-step by clicking on the Next function key, or you can skip

Strany 22 - XPLORER TOUCH ICON BUTTONS

29 An auto circuit detection window is displayed to select the detected circuit type, nominal voltage, current and frequency. Parameters that match ex

Strany 23 - XPLORER HOME MONITORING PAGE

3 ADVERTENCIA Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda este manual a

Strany 24 - Remember!

30 Monitoring Modes The Xplorer provides nine monitoring modes of operation from which to monitor and capture data relevant to the user’s application.

Strany 25 - SETUP MONITORING

31 Xplorer can help locate failures detected in various components of assorted equipment by recording an extended period of cycle-by-cycle data to cap

Strany 26 - Measurement Connections

32 After selecting a monitoring mode, press the Trigger Limits tab or press Next. The Limits screen will vary according to the selected monitoring mod

Strany 27 - Wizard Setup

33 The Xplorer uses four different algorithms to detect and record transients, while Dranetz HDPQ Guide and Visa have three. You have the option to ch

Strany 28

34  Set RMS Diff Transients – use to set the rms distortion waveshape limit. The rms deviation algorithm subtracts the same point-on-wave sample val

Strany 29

35  XTRIG Channels – use to set the trigger channels/parameters for waveform capture to determine which channel’s data will be saved when a trigger

Strany 30

36 Monitoring Mode for EN50160 Voltage Compliance The following screen appears if the selected monitoring mode is Voltage Compliance (EN50160): If

Strany 31

37 Under the Stop monitoring options, select one from the following:  Storage full - to end monitoring when memory storage is full  Delay - use th

Strany 32

38 Exit Setup At the end of the Wizard Setup, the Exit Setup screen prompts you to either accept the setup changes or not, before going on to start mo

Strany 33

39 Load Setup Template The Xplorer lists the setup template files (.set) stored in internal memory or external USB device, along with wiring configura

Strany 34

4 WARNUNG Der falsche Anschluß dieses Gerätes kann Tod, schwere Verletzungen oder Feuer verursachen. Bevor Sie dieses Instrument anschließen, müssen S

Strany 35

40 NOTE: The icons on the screen indicate the status of action you take with a particular session data file. Select (highlight) the desired session d

Strany 36

41 Change Instrument Configuration The Xplorer lets you manage the instrument to ensure that it runs efficiently, and the instrument is set up accordi

Strany 37

42 INSTRUMENT SETTINGS Instrument settings describe the miscellaneous tasks that you can perform to keep the Xplorer running efficiently. These are ta

Strany 38 - Monitor Same Circuit

43 Set Up Communications Options Communications setting is where you enter instrument-specific information to enable the Xplorer to communicate to ext

Strany 39 - Load Data File from Memory

44 Download Data Remotely via Network, WiFi & Bluetooth PAN 1) Navigate to the Manage Memory screen (Instrument Settings > Manage Memory). Sel

Strany 40

45 Download Data via USB Connection 1) Plug the small end of the USB active sync cable into the small USB connector on the right side of the HDPQ ins

Strany 41 - View/Save Monitoring

46 REAL TIME METER MODES Scope Mode Scope mode functions as an oscilloscope, displaying real-time waveforms of voltage and current for up to eight ch

Strany 42

47 Text Display Meters (tabular) Text display meter screens are displayed in tabular form. The metered parameters are logically separated into the fol

Strany 43

48 Harmonics Harmonics display the amplitude and phase of each harmonic to the 127th harmonic in both graphical and textual format. You can select whi

Strany 44

49 Strip Chart Recorder Strip Chart Recorder displays a real-time auto-scaled graph of selected parameters, updated once every 3 seconds. The initial

Strany 45

5 Caution, refer to accompanying documents (this manual). Alternating current (AC) operation of the terminal or device. Direct current (DC) op

Strany 46 - REAL TIME METER MODES

50 STORED DATA FUNCTIONS AND DISPLAYS The Xplorer offers a graphical, information-packed, and easy to navigate display of event data. Trend, Event Lis

Strany 47 - Dashboard

51 Trend Plot Users can generate time plots or trend visualizations for all journalled data combined with min/max/avg recordings of that parameter. Mo

Strany 48 - Phasor Display

52 Event List Presents a summary of all captured events in the order in which they occurred. Each event entry contains the date and time when the even

Strany 49 - Strip Chart Recorder

53 Event Plot (rms) Event rms plot displays the actual voltage and/or current rms that occurred when a certain threshold parameter was crossed. The

Strany 50 - Event Data and Reports Menu

54 Event Detail Event detail screen is generated for each event. Event details show the triggered parameters and event data saved by the instrument, a

Strany 51

55 REPORTS You have the option to view and set up data via the Voltage Compliance Report, Energy/Demand Audit Report, Harmonics Statistics Report or t

Strany 52

56 You can view component graphs for three parameters using the soft keys provided - Frequency for Power Frequency graph, Harmonics for Harmonic graph

Strany 53

57 Min/Max The Min/Max table displays the minimum and maximum values for Power Frequency and RMS Voltage, along with the time and date of occurrence.

Strany 54

58 Harmonics Statistics Report Harmonics Statistics Report allows you to set up a harmonic statistics report, based on the 3-second data calculating t

Strany 55 - REPORTS

59 General Specifications Dimensions: Size: 10” Width x 8” Height x 2.75” Depth (25.4 x 20.3 x 7cm) Weight: 4.2 pounds (1.9 kg) Envir

Strany 56

6 TABLE OF CONTENTS Introduction…………………………………………….…… 8 Getting Started……………………………………………... 9 Connecting to AC Power Source………………...………... 10 Co

Strany 57 - Energy and Demand Report

60 Statements and Notices (cont.) Statement of Reliability The information in this Quick Reference Guide has been reviewed and is believed to be enti

Strany 58 - Mini-Report Viewer

7 Trend with Event Markers..……………………………...…. 51 Event List.………………………………………………….… 52 Event Plot (rms)……………...…………………………...…. 53 Event Waveform..…

Strany 59 - Statements and Notices

8 INTRODUCTION The Dranetz HDPQ® Xplorer, Xplorer 400, Guide and Visa are portable, hand-held, eight-channel power quality meter/monitors which are v

Strany 60

9 GETTING STARTED IMPORTANT NOTICE  Charge Battery Before Use Always charge the battery fully before using the instrument! The instrument will fu